Skip to content
← All articles
GENERAL

Three Cleaning Challenges Around HACCP-Controlled Zones — and Where Dry Steam May Help

Three structural gaps that sanitation reviews can raise at zone boundaries — here is what they are and where high-temperature dry steam can support the cleaning process.

Published May 28, 2026·5 min read
Three Cleaning Challenges Around HACCP-Controlled Zones — and Where Dry Steam May Help

A food-plant sanitation audit should be a confirmation, not a discovery session. Three zone-boundary issues are worth checking before the auditor does. They are as much a question of design as of effort: they arise where HACCP zone boundaries meet equipment that was never designed with cleanability as a primary requirement.

Three issues worth checking before an audit

1. Condensate and residues at zone transition points. HACCP zone boundaries — typically the line between a high-care zone and a lower-risk area — are defined by physical barriers, airlocks or clear procedural separation. High-pressure wet cleaning can generate aerosol and pooling water, and both have to be managed so that they do not carry contamination across the boundary. Chemical cleaning and disinfection can be appropriate and validated; at zone edges, what matters is that residues and rinse water are handled exactly as the validated procedure requires. A failed swab at a zone boundary is followed by corrective action under the site’s own hygiene plan.

2. Hard-to-reach geometry on zone-boundary equipment. Conveyor undercarriages, frame welds, roller bearings and the undersides of transfer plates sit exactly where zone boundaries are drawn — and they are the features least accessible to manual cleaning or spray nozzles. Welded joints are often rougher than the surrounding stainless steel, and rough or recessed surfaces are harder both to clean and to verify. Auditors checking equipment against hygienic-design requirements such as EN 1672-2 may ask how these surfaces are shown to reach the required hygiene level. More chemistry or more pressure does not automatically solve a geometry problem: the method has to reach the recess, and its effect has to be verified.

3. A cleaning window that keeps shrinking. When sanitation requires line stoppage, cool-down, chemical application, dwell time, rinse and dry-out before restart, the realistic cleaning window shrinks. Production pressure can shorten dwell times, and a shortened dwell time may no longer match what the plant’s validated procedure specifies. When an auditor compares time-stamped cleaning records with production logs, shortened cycles become visible. The question is whether the method and the available cleaning window still fit together.

Where high-temperature dry steam may help with all three

Professional dry-steam equipment does not work like a pressure washer. The steam leaves the nozzle at a far lower pressure, at a temperature at or above the boiling point of water — how hot it is at the target depends on distance and dwell. Dry steam is a low-water process: steam condenses when it transfers heat to a cooler surface, and the amount of condensate and the drying time depend on the machine, accessory, surface, dwell and application. The result actually achieved on a surface depends on that full application — the temperature reached at the target, dwell time, distance and accessory — not on boiler pressure alone. That matters in three ways.

First, less splash. Low-pressure dry steam does not drive bulk water at the surface the way a high-pressure washer does, which can reduce splashing and pooling close to a zone boundary; whether it does on your line is checked during the test. Whether barriers or other measures are still needed is decided by the site’s own procedure, not by the machine.

Second, heat can reach geometry that spray nozzles struggle with: around roller bearings, into weld recesses and under transfer plates. We do not publish a percentage reduction — a figure such as 99.9% only means something when it is tied to a named organism, a temperature and a contact time, measured under a validated protocol. ATP may support rapid organic-residue monitoring; it does not prove microbial reduction or replace microbiological validation. Pure steam introduces no detergent or disinfectant residue during the steam step; whether rinsing or other chemistry is still required elsewhere is set by the facility’s validated hygiene plan.

Third, the cleaning window. Dry steam may reduce rinse, dry-out, chemistry or cleaning-window time in suitable applications. We measure the actual effect on the customer’s process rather than publishing a universal time saving: cleaning time, labour, chemistry, water and downtime, before and after a test on the site’s own equipment.

Get a tailored demo at your site →

What the documentation has to show

A food-safety system based on HACCP requires records showing that cleaning — usually part of the prerequisite programmes rather than a critical control point — is carried out at the specified frequency and to the specified standard. Where dry steam is part of the procedure, that evidence can include the operator’s record of the settings used, the operator’s sign-off and the verification checks the site has defined. Where chemistry or rinsing remain part of the validated procedure, their records remain part of the evidence too.

Sites certified to BRCGS Food Safety or IFS Food have to show that their cleaning procedures are effective; which steps must be formally validated follows from the standard and the site’s own hazard analysis. A dry-steam step can be part of such a procedure once its effect has been checked on the site’s own equipment and surfaces. The certification body assesses the procedure and its evidence — not the cleaning method on its own.

The practical starting point is a zone-boundary review of your own site before the external auditor does it. Identify the three or four pieces of equipment that sit at zone transitions, check the surface finish and accessibility of their undercarriage geometry, and pull the last six months of cleaning records to verify that dwell times were actually met. If any of those checks produces a finding, review the method and the procedure together. High-temperature dry steam is one method that may help with all three issues described above, provided the application is validated on the site’s own equipment and surfaces — and we measure its effect during a test rather than promising it in advance.