Skip to content
Electrical panels · Industry

Clean electrical panels and cabinets — no water, often without disassembly

Dry ice (-78.5 °C) removes dust, oil and deposits from electrical components through a dry process — no water as the cleaning medium and no secondary abrasive medium and no blasting medium to clean up afterwards; the effect on the surface depends on material, contamination and working parameters.

CRYONOMIC COB 71
CRYONOMIC COB 71
-78.5 °C
dry ice pellets
0
water in the process
no
secondary blasting medium
test
sensitive surfaces first

Cleaning panels with compressed air only moves the dust around, and with liquids you risk short circuits and long shutdowns for drying.

Conductive dust, oil and deposits on panels, motors and automation are not just a cleanliness problem — they cause overheating, intermittent faults and unplanned shutdowns. And the classic methods each have a hidden cost: compressed air only moves the dust around, liquids bring the risk of short circuits and hours of drying, and abrasive sandblasting wears the components.

Dry-ice blasting solves exactly this trade-off. The CO₂ pellets at -78.5 °C lift the deposits through a thermal shock, then sublimate — they pass directly into gas, without leaving water, sand or a secondary blasting medium. The process is dry, so the equipment can often be cleaned without full disassembly, following electrical safety procedures. Surface effect depends on substrate, contamination and process parameters; test sensitive surfaces first.

Below you will find the mechanism, the relevant parameters, the recommended equipment and what it means for downtime and risk.

Consequences

What you risk with classic methods

  • !Short circuits and faults caused by moisture
  • !Long shutdowns for disassembly and drying
  • !Conductive dust left behind that causes overheating
  • !Wear on components from abrasive cleaning
  • !Risk to personnel when working with liquids near live voltage

The solution

How dry ice cleans — dry and without water

The dry ice pellets are projected onto the surface at high speed. The cold lifts the deposits, and the pellets sublimate (pass directly from solid to gas) — no water, no granules and no blasting medium to clean up remains. Surface effect depends on substrate, contamination and process parameters; test sensitive surfaces first.

ParameterValueRole
Cleaning mediumCO₂ pellets, -78.5 °CLift the deposits through thermal shock
ResidueCO₂ gas and the removed dirtThe pellets sublimate; the removed dirt is collected
WaterzeroNo cleaning water and no conventional water-based drying stage; on energised equipment only after a site-specific safety review, including condensation and restart conditions
  • The process is dry, without water. Energised equipment is only cleaned after a site-specific electrical safety review, under the equipment manufacturer's procedures and with qualified personnel.
  • The pellets sublimate on impact — no water, sand or secondary residue to remove remains.
  • Surface effect on contacts, boards and insulation depends on substrate, contamination and process parameters — test first.
  • Often cleaned without full disassembly — in the right applications, the stop can be shorter, and we measure the real effect on your equipment.

See it for yourself

Electrical equipment cleaned with dry ice, without water

Curățare Generatoare cu Gheață Carbonică în Industria Energetică • Aparat Cryonomic • HD CleanersCommentary in Romanian.

Who it is for

The same problem, across several industries

Manufacturing & automationHeavy industryEnergy & electrical substationsIndustrial maintenanceFacility management

ROI and risk

No water near electronics — downtime, measured on site

  • Often without full disassembly; in the right applications, shutdowns can be shorter — we measure them at the demonstration
  • No wet-cleaning water near electrical components
  • No blasting medium left behind — only the detached deposits, which still have to be collected
  • AUTONOM rental: monthly rental expenses may be tax-deductible, depending on your tax situation

Frequently asked questions

What we get asked most

Is it safe to clean electrical components with dry ice?+
The process is dry, without water, so the water-specific risk of wet cleaning does not arise. Whether equipment may be cleaned while energised is not decided by the cleaning method: energised equipment requires a site-specific electrical safety review, the equipment manufacturer's procedures and qualified personnel. As a rule, the work is done on de-energised equipment.
Is there residue after cleaning?+
The dry-ice medium sublimates after impact, so no secondary blasting medium remains. Removed contamination still has to be managed — no water, sand or other granules to collect.
Does the equipment have to be disassembled?+
Often not, or only partially. Because no water is used, many components can be cleaned in place, which, in the right applications, can shorten downtime — we measure the real effect on your equipment.
Does dry ice wear the components?+
Surface effect depends on substrate, contamination and process parameters; test sensitive surfaces first (contacts, boards, insulation). Unlike classic sandblasting, no abrasive medium is added.
25+
years of industrial expertise
2
European trademarks · HD Cleaners® · TIPORA®
GRENKE
equipment leasing
AUTONOM
long-term equipment rental

Show us what needs cleaning.
We'll help you decide what to test first.

Send us a few details, photos or a short video of the application. Within one working day, a technical sales consultant will review it and come back with the next best step — additional questions, a first recommendation or a proposed test.

WhatsApp
Strada Zorilor 16, Miercurea Ciuc
+40 742 446 516info@hdcleaners.ro